Version 12 (modified by 13 years ago) ( diff ) | ,
---|
Known Problems
These are the known problems that may affect many users. Problems which only affect 1 or 2 unique systems are not listed here. Since these are already known problems, you do not need to open a ticket or report any of the problems listed on this page.
Suspend / Resume
Suspend / Resume only works on a very small number of systems. If Suspend / Resume works for you, consider yourself among the few lucky ones. If it does not work for you, please wait for more progress to be made and try a later version. Please do not report problems with Suspend / Resume at this time.
Power Off
There is a known problem with almost all utilities that power off your system, including the xworkplace eComStation extended shutdown.
The problem occurs when these utilities shut down the file systems before the power off routine has been paged into memory. When the utility calls the routine to power off the system, the kernel can't page it into memory because the file systems have been stopped. This is not a defect in ACPI.PSD or related software and cannot be fixed in the any of the ACPI software because the ACPI software does not get control at the appropriate time. It must be fixed in the power off utility.
Because of the nature of this defect, power off utilities with the defect may have randomly worked in the past because the power off routine may or may not have been in memory for some other reason. If things move around in memory, or some other program causes the routine to get paged in, the power off may have worked. The only way to reliably fix the defect is to fix the power off utility.
You can test the power off functionality of ACPI by itself by opening a command window and typing the following command:
acpistat poweroff
This command properly makes sure the power off routine is in memory before stopping the file systems. Make sure you are using the latest version of acpistat.exe.
If acpistat poweroff successfully powers off your system, then there is nothing wrong with any of the ACPI software. Do not report this as a problem with ACPI. Instead report the problem to the appropriate place for your shutdown utility (xworkplace, for example).
Systems with ACPI from Award
There is a known problem with the ACPI provided by Award. These systems typically won't boot. The boot hangs with the boot logo on the screen.
You can determine if your BIOS has this ACPI in it by opening a command window and typing the following command:
iasl -g
This command will work whether or not ACPI.PSD is installed. The command will output a bunch of lines to the screen which will look something like this:
ACPI: RSDP F8CA0 14 (v0 VIAK8M) ACPI: RSDT 7FFF3040 2C (v1 VIAK8M AWRDACPI 42302E31 AWRD 0) ACPI: FACP 7FFF30C0 74 (v1 VIAK8M AWRDACPI 42302E31 AWRD 0) ACPI: DSDT 7FFF3180 5139 (v1 VIAK8M AWRDACPI 1000 MSFT 100000E) ACPI: FACS 7FFF0000 40 ACPI: APIC 7FFF8300 5A (v1 VIAK8M AWRDACPI 42302E31 AWRD 0)
If the line which starts with "ACPI: DSDT" has the string "AWRDACPI" in it, then your system has the Award ACPI in it. If your system has the Award ACPI in it, then you do not need to open a ticket. I already know about the problem and I am working on an fix for it.
The iasl -g command also writes a few files to the current directory which are unneeded and you can delete them.
Immediate suspend due to misbehaving SLPB device
Some systems enter suspend immediately after AcpiDaemon is started. This is due to a misbehaving SLPB device which generates repeating suspend requests. If you have this problem, don't run the AcpiDaemon until a version with a fix or workaround is released.
SCSI drivers
While this is not an ACPI.PSD problem, I am listing it here because the PSD can reconfigure the system in a way that the drivers don't like.
It appears that most SCSI drivers have one or both of 2 problems.
- Some SCSI drivers cannot handle interrupt numbers greater than 15.
- Some SCSI drivers cannot handle the interrupt being changed from what the BIOS has set it to, regardless of whether or not it is greater than 15.
Both of these problems can be handled by using the /VW switch.